High Pressure / High Temperature Adsorption
 
Magnetic Suspension Balance

For measurement of mass change due to high pressure and high temperature precision measurement system for Sorption, Density Supercritical Fluid Extraction, Diffusion, Thermogravimetry, Surface tension, Pyrolysis, Viscosity, Corrosion, Decomposition, Drying, Polymerization, Coating, Permeation.

Click for Details

 

Isosorp Gas : Adsorption by Gravimetry.

Using a patented design Magnetic Suspension Balance almost all kind of Gas Adsorption measurement can be performed.

Click for Details

 

Isosorp Vapour

Uses patented design Magnetic Suspension Balance for Vapour adsorption.

Click for Details

   
Products from L & C Science & Technology Inc. USA
Standard and Customized dual bed system for all levels of PSA and VSA gas separation

Dual-bed configuration with bed dimensions 2” ID and 24” high… nominally providing 1000 cc bed volume. Based on the application, adsorbate bed volume can range from 300 cc to 1200 cc Gas flow rates from 1liter/min to 25 liters/min depending on application. Pressure range up to 1200 psia (83 bars) with controlled vacuum testing down to .1 Torrs and general vacuum functions for desorbing of materials. Experimental temperature range is 5°C to 60°C with fully automated drying cycles to 300°C Precision temperature and pressure/vacuum control provided by system’s software. Complete computer system provides all needed proprietary L&C software for broad range of PSA and VSA gas separation protocols. Optional custom monitoring systems include gas chromatograph, mass spectrometer, etc.
  A family of Bench top Relative Humidity Generators
 

RH-200 Relative Humidity

Range from 3% to 95% RH, with control to ±1.0%RH

Temperature range from Ambient to 50°C at target instrument.

Dew Point range from -25°C to 50°C.

Standard flow rate is 500 cc/min with options up to 5 liters/min.

RH-200 uses two mass flow controllers to regulate the flow of dry and saturated gas

 

HG-200 Humidity Generator

Relative Humidity from 2% to 95% RH depending on temperature of receiving instrument, delivered with accuracy of ±2.0%

Dew Point Temperature from 0.2°C to 40°C with option to 85°C

HG-100’s humidifier is manually preset to generate the output gas dew point temperature corresponding to the desired %RH at target instrument.

Standard flow rate is 500 cc/min with optional ranges up to 1 liter/min